More on Saniflex

Measure-cut-connect: 1. Screw one speed fit in the angle valve that supplies the water and the second speed fit in the water tank of basin. 2. Push the pipe into the speed fit of the angle valve until you hear the characteristic click of successful connection. 3. Measure the required length of pipe till the second (opposite) speed fit and after that cut the main pipe and the equal length of corrugated pipe. 4. Put the main pipe inside of the corrugated one and connect one end of the main pipe with the angle valve. Push the corrugated pipe so that there is a sufficient length of the main inner pipe to be connected with the speed fit until the characteristic click. Fix the corrugated pipe.

TECHNICAL CHARACTERISTICS-PROPERTIES


Control Tests for quality certification:

TEST

SPECIFICATIONS

REQUIRENMENTS

COMMENTS

Hydrostatic pressure

EN ISO 15875-5

Paragraph.4.2

12,5bar-95oC

for 1000h

Rotation

Temperature

EN ISO 15875-5

Paragraph.4.5

10bar with rotation 90oC/20oC

per15min for 5000 circles

Rotation

Pressure

EN ISO 15875-5

Paragraph.4.6

23oC with rotation 0,5bar/15bar

per 2sec for 10000 circles